1. Bayonet Plate Installation
- Location Choose Karna:
- Sensor ko tank ke center mein install karo, jahan sabse zyada deep bottom point ho.
- Agar center mein install karna mushkil ho, to sensor ko displace kar sakte ho, par isse fuel level fluctuations badh sakti hain.
- Mark aur Drill Karna:
- Center point mark karo aur measuring electrodes ke liye 38 mm bimetal drill bit se holes banao.
- Safety measures zaroor follow karo: gasoline tanks aur large diesel fuel storage tanks ko drill karne se pehle evaporate ya paani se fill kar lo.
- Screws Ke Liye Holes Drill Karna:
- Bayonet plate ke holes match karne ke liye 5 holes screws ya self-tapping screws ke liye banao.
- Gasket Aur Bayonet Plate Install Karna:
- Mounting kit se flat rubber gasket ko container aur bayonet plate ke beech mein rakho.
- Bayonet plate ko screws ya self-tapping screws se fix karo.
2. Sensor Cutting
- Length Measure Karna:
- Bayonet ke top surface aur tank ke bottom ke beech distance 𝑆 measure karo.
- Cutting Length Determine Karna:
- Sensor cutting length 𝐿1 ko sensor length 𝐿 se subtract kar ke nikaalo, agar bottom stop installed hai to 30 mm subtract karo. Stationary containers ya 700 mm tak ke sensor length ke liye bottom stop install mat karo.
- Sensor Cut Karna:
- Required length ke hisaab se hacksaw se sensor cut karo.
3. Sensor Installation
- Electrodes Connect Karna:
- Agar zaroorat ho to measuring electrodes ko sensor ke electronic module se connect karo. Pehle inner electrode ko screw karo, phir outer electrode ko.
- Bottom Stop Install Karna:
- Bottom stop spring ko install karo.
- O-ring Insert Karna:
- Rubber seal ring (O-ring) ko bayonet ke slot mein rakho.
- Sensor Install Karna:
- Assembled sensor ko bayonet mount mein insert karo, press karo till it stops aur sensor ko clockwise turn karo jab tak fix na ho jaye. Ensure karo ki housing ke edges bayonet plate ke edges se align ho jaye.
- Sealant Application:
- Agar sealant use kar rahe ho to dhyan rakho ki excess sealant sensor case aur tank opening ko overlap na kare, warna sensor ke top part ke drain holes se air tank mein wapis nahi ja paayegi .
4. Installation on Cylinder Tank (agar applicable ho)
- Cylinder tank pe sensor install karne ke liye shaped gasket Dominator SHIM ka use karo.
5. Installation of Eurosens Dominator BT
- Bluetooth signal ke liye ensure karo ki antenna icon sensor pe receiver (monitoring terminal ya data receiver eurosens Bt-COM) ki taraf directed ho.